fits model: Tsx. make: Acura. year: 2002–2008.

( Brand: Topower ), ( Manufacturer Part Number: TO11528AS892P ), ( Type: Sensor ), ( Manufacturer Warranty: 1 Year ), ( Custom Bundle: No ), ( Fitment Type: Direct Replacement ), ( Thread Size: M18 ), ( Terminal Type: Blade ), ( Universal Or Specific Fit: Specific ), ( Attachment Method: Screw-on ), ( Connector Gender: Female ), ( Wire Harness Length: 39.37 In ), ( Sensor Type: Heated ), ( Output Signal Range: 0.2v To 0.8v ), ( Mounting Type: Threaded ), ( Position: Downstream, Sensor 2 ), ( Features: Direct Fit )
Introducing the top-tier TOWER Power O2 Sensor, specifically designed for the downstream post-rear position in 2004-2008 Acura TSX models equipped with a 2.4L engine. This oxygen sensor is an essential component of the vehicle's exhaust system, responsible for monitoring the exhaust gases' oxygen content and adjusting the engine's fuel-air mixture for optimal performance and emission compliance.
The TOWER Power O2 Sensor is engineered using advanced sensor technology and materials. It boasts a high-temperature ceramic element capable of withstanding extreme exhaust temperatures, ensuring reliable and accurate readings. The sensor's stainless steel housing is both corrosion-resistant and durable, protecting the sensitive components from the harsh exhaust environment.
This OEM-grade replacement sensor features a wide operating temperature range of -40 F to 1752 F (-40 C to 900 C), ensuring it functions effectively in various driving conditions. It is also designed to meet or exceed the original equipment specifications, ensuring a seamless fit and reliable performance.
The TOWER Power O2 Sensor comes with a user-friendly installation process. It is designed to plug-and-play, requiring no modifications or additional wiring. The sensor's compact size and precise connector design make it an easy replacement for the worn-out or faulty original sensor.
By upgrading to the TOWER Power O2 Sensor, you can enjoy improved fuel efficiency, enhanced engine performance, and reduced emissions. It is an investment in the long-term health and reliability of your Acura TSX, ensuring a smoother and more enjoyable driving experience.
In summary, the TOWER Power O2 Sensor for the downstream post-rear position in 2004-2008 Acura TSX 2.4L models is an essential upgrade for maintaining optimal engine performance and emission compliance. Its advanced sensor technology, durable materials, and easy installation process make it a top choice for vehicle owners seeking a reliable and high-performing replacement sensor.
The TO34-11528-AS892P is an oxygen sensor (O2 sensor) part number specific to the downstream post-rear position in the 2.4L engine of the 2004-2008 Acura TSX. This analysis compares the pros and cons of buying an Original Equipment Manufacturer (OEM) versus an aftermarket O2 sensor for this application.
OEM Oxygen Sensor (TO34-11528-AS892P): Pros:1. Fitment and Functionality: Guaranteed to fit and function as intended since it is specifically designed by the vehicle manufacturer.
2. Warranty: Usually comes with a warranty from the dealership or the vehicle manufacturer, providing peace of mind and potential savings in the event of failure.
3. OEM Quality: Built to the same standards as the original sensor, ensuring optimal performance and longevity.
Cons:1. Cost: OEM sensors are generally more expensive than aftermarket sensors due to their branding and the additional warranty.
Aftermarket Oxygen Sensor (TO34-11528-AS892P): Pros:1. Cost: Aftermarket sensors are typically less expensive than OEM sensors, making them an attractive option for budget-conscious consumers.
2. Variety: Aftermarket sensors are produced by multiple manufacturers, providing a wider selection of brands and price points.
3. Performance: Many aftermarket sensors offer improved sensitivity and durability, which can lead to better fuel efficiency and longer lifespan.
Cons:1. Fitment: There is a slight chance that the aftermarket sensor may not fit perfectly or function as intended, although most reputable brands ensure proper fitment.
2. Warranty: Aftermarket sensors usually do not come with a warranty, leaving consumers without manufacturer support in the event of failure.
3. Quality Variability: The quality of aftermarket sensors can vary greatly between different brands and models.
Conclusion:When considering the purchase of an O2 sensor (TO34-11528-AS892P) for a 2004-2008 Acura TSX 2.4L, both OEM and aftermarket options come with their unique advantages and disadvantages. Ultimately, the decision comes down to personal preference, budget, and desired level of warranty coverage.
If priority is given to guaranteed fitment, peace of mind, and OEM quality, an OEM sensor would be the recommended choice. However, for cost-conscious consumers seeking improved performance or a wider selection of options, an aftermarket sensor would be a suitable alternative, as long as they choose a reputable brand.
Recommendation:Based on the information provided, it is recommended to research and consider both OEM and aftermarket options before making a final decision. Factors such as budget, desired warranty coverage, and preferred brand reputation should be taken into account when selecting the best O2 sensor for your specific application.
The following information is for instructional and guidance reference only. Step 2 - By using a regular socket it minimizes potential damage to the sensor body and threads, this technique helps avoid stripping old upon removal. Check engine light on A reduction in fuel economy. If the car has diagnostic trouble codes, they will need to be cleared.
2004 2008 Acura TSX 2.4L, 2003 2007 Honda Accord 2.4L. Your catalytic converter fails unexpectedly Exhaust emissions reach undesirable levels. ONLY a defective sensor after tested by voltmeter is applied to manufacturer warranty. If Check Engine Light is on or an OBDII Trouble/Fault code occurs after installation, check the sensor with a voltmeter as below.
Gently install the new oxygen sensor by hand while keeping wiring and connector free from bends. Oxygen Sensors Location. New List Item. Must Know Before Buying.
How to install the oxygen sensor. Step 1 - Some sensors are equipped with a heat shield that must be removed before the sensor removal, this is performed by removing any mounting bolts. Note: some replacement sensors have a universal electrical connector that must be configured to the wiring of old sensor. There're many different codes for specific functional failures, which are NOT necessarily relevant to the sensor.
If the sensor is good, further diagnosis required.